Hint:  Click on column headings to sort A-Z or Z-A.

Latest update:   September 12, 2017

PSRC Standards

C - Systems Protection, D - Line Protection, H - Relaying Communications,

I - Relaying Practices, J - Rotating Machinery, K - Substation Protection

No. Subcommittee Title
 
C37.117 C IEEE Guide for the Application of Protective Relays Used for Abnormal Frequency Load Shedding and Restoration
C37.233 C IEEE Guide for Power System Protection Testing
C37.242 C IEEE Guide for Synchronization Calibration Testing and Installation of Phasor Measurement Units (PMUs) for Power System Protection and Control
C37.244 C IEEE Guide for Phasor Data Concentrator Requirements for Power System Protection Control and    Monitoring 
C37.246 C Guide for Protection Systems of Transmission to Generation Interconnections
C37.247 C Standard for Phasor Data Concentrators for Power Systems
C37.250 C Guide for Engineering, Implementation, and Management of System Integrity Protection Schemes
C37.104 D IEEE Guide for Automatic Reclosing of Circuit Breakers for AC Distribution and Transmission Lines
C37.113 D IEEE Guide for Protective Relay Applications to Transmission Lines
C37.114 D IEEE Guide for Determining Fault Location on AC Transmission and Distribution Lines
C37.230 D IEEE Guide for Protective Relay Applications to Distribution Lines
C37.243 D Guide for Application of Digital Line Current Differential Relays Using Digital Communications
1646 H Standard Communication Delivery Time Performance Requirements for Electric Power Substation Automation
2030.100 H IEEE Recommended Practice for Implementing an IEC 61850-Based Substation Communications, Protection, Monitoring, and Control System
2030.101 H Guide for Designing a Time Synchronization System for Power Substations
60255-118-1 H IEEE Standard for Synchrophasor Measurements for Power Systems
C37.1.2 H Recommended Practice for Databases Used in Utility Automation Systems
C37.111 H IEEE/IEC Measuring relays and protection equipment - Part 24: Common format for transient data exchange (COMTRADE) for power systems
C37.118.1 H IEEE Standard for Synchrophasor Measurements for Power Systems
C37.118.1a H IEEE Standard for Synchrophasor Measurements for Power Systems
C37.118.2 H IEEE Standard for Synchrophasor Measurements for Power Systems -- Amendment 1: Modification of Selected Performance Requirements
C37.232 H IEEE Standard for Common Format for Naming Time Sequence Data Files (COMNAME)
C37.236 H IEEE Guide for Power System Protective Relay Applications Over Digital Communication Channels
C37.237 H Standard Requirements for Time Tags Created by Intelligent Electronic Devices - COMTAG(TM)
C37.238 H IEEE Standard Profile for Use of IEEE 1588 Precision Time Protocol in Power System Applications
C37.239 H IEEE Standard for Common Format for Event Data Exchange (COMFEDE) for Power Systems
C37.240 H IEEE Standard Cybersecurity Requirements for Substation Automation, Protection, and Control Systems
C37.248 H Guide for Common Format for Naming Intelligent Electronic Devices (COMDEV)
C37.249 H Guide for Cyber Security of Protection Related Data Files (joint with Subs)
C37.251 H Standard for Common Protection and Control Settings or Configuration Data Format (COMSET)
C37.93 H IEEE Guide for Power System Protective Relay Applications of Audio Tones Over Voice Grade Channels
C37.94 H IEEE Standard for N Times 64 Kilobit Per Second Optical Fiber Interfaces Between Teleprotection and Multiplexer Equipment
1613 I Standard for Environmental and Testing Requirements for Intelligent Electronic Devices (IEDs) Installed in Transmission and Distribution Facilities
C37.1.1 I Standard for Input and Output Requirements and Testing Methodology for Intelligent Electronic Devices (IEDs)
C37.103 I IEEE Guide for Differential and Polarizing Relay Circuit Testing
C37.105 I IEEE Standard for Qualifying Class 1E Protective Relays and Auxiliaries 
C37.110 I IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes
C37.110-2007/Cor 1 I IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes Corrigendum 1: Corrections to Equation 18 and Equation 19
C37.2 I Standard Electrical Power System Device Function Numbers, Acronyms, and Contact Designations
C37.231 I IEEE Recommended Practice for Microprocessor-Based Protection Equipment Firmware Control
C37.235 I IEEE Guide for the Application of Rogowski Coils Used for Protective Relaying Purposes
C37.241 I Guide for Application of Optical Instrument Transformers for Protective Relaying
C37.90 I IEEE Standard for Relays and Relay Systems Associated with Electric Power Apparatus
C37.90.1 I IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus
C37.90.2 I IEEE Standard for Withstand Capability of Relay Systems to Radiated Electromagnetic Interference from Transceivers
C37.90.3 I IEEE Standard Electrostatic Discharge Tests for Protective Relays
C37.92 I IEEE Standard for Analog Inputs to Protective Relays From Electronic Voltage and Current Transducers
C37.98 I IEEE Standard for Seismic Qualification Testing of Protective Relays and Auxiliaries for Nuclear Facilities
C57.13.1 I IEEE Guide for Field Testing of Relaying Current Transformers
C57.13.3 I IEEE Guide for Grounding of Instrument Transformer Secondary Circuits and Cases
C37.101 J IEEE Guide for Generator Ground Protection
C37.101-2006/Cor 1 J IEEE Guide for Generator Ground Protection - Corrigendum 1: Annex A.2 Phasor Analysis (Informative)
C37.102 J IEEE Guide for AC Generator Protection
C37.106 J IEEE Guide for Abnormal Frequency Protection for Power Generating Plants
C37.96 J IEEE Guide for AC Motor Protection
C37.108 K IEEE Guide for the Protection of Network Transformers
C37.109 K IEEE Guide for the Protection of Shunt Reactors
C37.112 K IEEE Standard Inverse-Time Characteristic Equations for Overcurrent Relays
C37.116 K IEEE Guide for Protective Relay Application to Transmission-Line Series Capacitor Banks
C37.119 K IEEE Guide for Breaker Failure Protection of Power Circuit Breakers
C37.234 K IEEE Guide for Protective Relay Applications to Power System Buses
C37.245 K Guide for the Application of Protective Relaying for Phase Shifting Transformers
C37.91 K IEEE Guide for Protecting Power Transformers
C37.95 K IEEE Guide for Protective Relaying of Utility-Consumer Interconnections
C37.99 K IEEE Guide for the Protection of Shunt Capacitor Banks